14-----26302R11 fail locked electric strike

Model with basic equipment.

  • Suitable for all common striking plates
  • Can be combined with striking plates with latch bolt guide (standard) without FaFix®
  • Due to 180° fitting, can be used DIN right and left

Voltage: 8-16 V AC/DC
Fail-locked: Yes
Break-in resistance: 6500 N
Height: 90 mm
Width: 20 mm
Depth: 28,2 mm
Operating temperature range: -15 °C to +40 °C
Installation position: vertical
Material housing: Die-cast zinc
Latch material: Steel
Material surface-mounted attachment: Die-cast zinc
Rated resistance: 16,50 Ω
DC-operating noise 8 V: 350 mA
AC current consumption 12 V: 500 mA
AC-current consumption 16 V: 700 mA
DC-current consumption (50% Residual ripple) 8 V: 470 mA
DC-current consumption (50% Residual ripple) 12 V: 710 mA
DC-current consumption (50% Residual ripple) 16 V: 940 mm
DC-current consumption (stabilized) 8 V: 485 mA
DC-current consumption (stabilized) 12 V: 725 mA DC-current consumption (stabilized) 16 V: 970 mA
AC-operating noise 8 V: loud [4]
AC-operating noise 12 V: low [1]
AC-operating noise 16 V: loud [4]
DC-operating noise 8 V: loud [4]
DC-operating noise 12 V: low [1]
DC-operating noise 16 V: low [1]
Max. latch preload AC operation 8 V: 110 N
Max. latch preload AC operation 12 V: 80 N
Max. latch preload AC operation 16 V: 100 N
Max. keep pre-load DC (50% Residual ripple) 8 V: 10 N
Max. latch preload DC (50% ripple) 12 V: 20 N
Max. latch preload DC (50% ripple) 16 V: 40 N Max. latch preload DC (stabilised) 8 V: 10 N
Max. latch preload DC (stabilised) 12 V: 10 N Max. latch preload DC (stabilised) 16 V: 20 N